Selected Corrosion Data

Hydrobromic Acid

Conc.
Wt.%

50°F

75°F

100°F

125°F

150°F

175°F

200°F

225°F

Boiling

10°C

24°C

38°C

52°C

66°C

79°C

93°C

107°C

2.5

-

-

-

-

-

-

-

-

-

5

-

-

-

-

-

-

-

-

0.08

7.5

-

-

-

-

-

-

-

-

-

10

-

-

-

-

-

0.01

0.05

-

0.21

15

-

-

-

-

-

-

-

-

-

20

-

-

-

-

0.04

0.31

0.37

-

0.47

25

-

-

-

-

-

-

-

-

-

30

-

-

0.11

0.17

0.24

0.31

0.37

-

0.68

40

-

-

0.09

0.14

0.20

0.28

0.34

-

0.85

All corrosion rates are in millimeters per year (mm/y); to convert to mils (thousandths of an inch) per year, divide by 0.0254.
Data are from Corrosion Laboratory Jobs 23-07 and 5-08.
All tests were performed in reagent grade acids under laboratory conditions; field tests are encouraged prior to industrial use.

Hydrobromic HYBRID-BC1

Hydrochloric Acid

Conc.
Wt.%

50°F

75°F

100°F

125°F

150°F

175°F

200°F

225°F

Boiling

10°C

24°C

38°C

52°C

66°C

79°C

93°C

107°C

1

-

-

-

-

-

-

0.01

-

0.01

1.5

-

-

-

-

-

-

0.01

-

0.06

2

-

-

-

-

-

-

0.02

-

0.10

2.5

-

-

-

-

-

-

0.04

-

0.15

3

-

-

-

-

-

-

0.08

-

0.21

3.5

-

-

-

-

-

-

-

-

-

4

-

-

-

-

-

-

-

-

-

4.5

-

-

-

-

-

-

-

-

-

5

-

-

-

<0.01

0.02

0.08

0.31

-

0.45

7.5

-

-

-

-

-

-

-

-

-

10

-

-

0.02

0.13

0.27

0.38

0.53

-

-

15

-

-

0.12

0.21

0.28

0.44

0.57

-

-

20

-

-

0.12

0.18

0.29

0.45

0.68

-

-

All corrosion rates are in millimeters per year (mm/y); to convert to mils (thousandths of an inch) per year, divide by 0.0254.
Data are from Corrosion Laboratory Jobs 23-07 and 5-08.
All tests were performed in reagent grade acids under laboratory conditions; field tests are encouraged prior to industrial use.

Hydrochloric HYBRID-BC1

Nitric Acid

Conc.
Wt.%

50°F

75°F

100°F

125°F

150°F

175°F

200°F

225°F

Boiling

10°C

24°C

38°C

52°C

66°C

79°C

93°C

107°C

10

-

-

-

-

-

0.04

0.07

-

0.13

20

-

-

-

0.05

0.15

-

-

-

-

30

-

-

0.07

0.13

0.28

0.74

4.72

-

-

40

-

-

0.10

0.20

-

-

-

-

-

50

-

-

0.11

0.29

0.98

4.45

17.40

-

-

60

-

-

0.14

0.40

-

-

-

-

-

70

-

0.08

0.19

0.54

2.62

9.54

20.52

-

-

All corrosion rates are in millimeters per year (mm/y); to convert to mils (thousandths of an inch) per year, divide by 0.0254.
Data are from Corrosion Laboratory Jobs 23-07 and 5-08.
All tests were performed in reagent grade acids under laboratory conditions; field tests are encouraged prior to industrial use.

Nitric HYBRID-BC1

Phosphoric Acid

Conc.
Wt.%

125°F

150°F

175°F

200°F

225°F

250°F

275°F

300°F

Boiling

52°C

66°C

79°C

93°C

107°C

121°C

135°C

149°C

50

-

-

-

-

-

-

-

-

0.12

60

-

-

-

-

-

-

-

-

-

65

-

-

-

-

-

-

-

-

-

70

-

-

-

-

-

0.11

-

-

0.19

75

-

-

-

-

-

0.02

-

-

0.20

80

-

-

-

-

-

0.02

0.02

-

0.33

85

-

-

-

-

-

0.01

0.02

0.46

0.67

All corrosion rates are in millimeters per year (mm/y); to convert to mils (thousandths of an inch) per year, divide by 0.0254.
Data are from Corrosion Laboratory Jobs 23-07 and 5-08.
All tests were performed in reagent grade acids under laboratory conditions; field tests are encouraged prior to industrial use.

Phosphoric HYBRID-BC1

Sulfuric Acid

Conc.
Wt.%

75°F

100°F

125°F

150°F

175°F

200°F

225°F

250°F

275°F

300°F

350°F

Boiling

24°C

38°C

52°C

66°C

79°C

93°C

107°C

121°C

135°C

149°C

177°C

1

-

-

-

-

-

-

-

-

-

-

-

-

2

-

-

-

-

-

-

-

-

-

-

-

-

3

-

-

-

-

-

-

-

-

-

-

-

-

4

-

-

-

-

-

-

-

-

-

-

-

-

5

-

-

-

-

-

-

-

-

-

-

-

-

10

-

-

-

-

-

0.07

-

-

-

-

-

0.03

20

-

-

-

-

-

-

-

-

-

-

-

0.06

30

-

-

-

-

-

0.08

-

-

-

-

-

0.09

40

-

-

-

-

-

-

-

-

-

-

-

-

50

-

-

-

-

-

0.06

0.11

-

-

-

-

0.24

60

-

-

-

-

-

-

-

-

-

-

-

-

70

-

-

-

-

-

0.03

0.11

0.22

1.71

-

-

-

80

-

-

-

-

-

-

0.05

0.24

0.52

-

-

-

90

-

-

-

-

-

0.03

0.06

0.14

0.38

0.94

-

-

96

-

-

-

-

-

-

0.11

0.21

0.45

1.11

-

-

All corrosion rates are in millimeters per year (mm/y); to convert to mils (thousandths of an inch) per year, divide by 0.0254.
Data are from Corrosion Laboratory Jobs 23-07 and 5-08.
All tests were performed in reagent grade acids under laboratory conditions; field tests are encouraged prior to industrial use.

Sulfuric HYBRID-BC1

Top