HAYNES® 214® alloy Site
Principal Features
Typical Applications
Oxidation Resistance
Carburization Resistance
Resistance to Chlorine-Bearing
Environments
Nitriding Resistance
Physical Properties
Modulus of Elasticity
Tensile Properties
Creep and Rupture Properties
Thermal Stability
Fabrication Characteristics
Welding
Health and Safety
HAYNES® 214® alloy
Technical Briefs
HAYNES® 214 ® alloy
Wire Information
Metallurgist Support
Sales Office Addresses
Tubular Products
Fittings & Flanges
|
| |
Typical Physical Properties |
| |
While not the most resistant alloy for
nitriding environments at traditional
1000°F to 1200°F (540°C to 650°C)
temperatures, HAYNES® 214® alloy exhibits
outstanding resistance at the higher
temperatures where its protective Al2O3 scale can form, even in
extremely low oxygen environments.
Tests were performed in flowing
ammonia at 1200, 1800 and 2000°F
(650, 980 and 1095°C) for 168 hours.
Nitrogen absorption was determined by technical analysis of samples
before and after exposure, and
knowledge of the exposed specimen
area.
|
|
|
| |
Temp., °F |
British Units |
Temp., °C |
Metric Units |
| Density |
Room |
0.291 lb/in.3 |
Room |
8.05 g/cm.3 |
| Melting Temperature |
2475-2550 |
|
1355-1400 |
|
|
| Electrical Resistivity |
Room |
53.5 microhm-in. |
Room |
135.9 microhm-cm |
| |
200 |
53.9 microhm-in. |
100 |
136.9 microhm-cm |
| |
400 |
53.9 microhm-in. |
200 |
136.9 microhm-cm |
| |
600 |
53.9 microhm-in. |
300 |
136.9 microhm-cm |
| |
800 |
54.3 microhm-in. |
400 |
137.7 microhm-cm |
| |
1000 |
54.3 microhm-in. |
500 |
137.9 microhm-cm |
| |
1200 |
53.5 microhm-in. |
600 |
136.8 microhm-cm |
| |
1400 |
51.6 microhm-in. |
700 |
133.7 microhm-cm |
| |
1600 |
49.6 microhm-in. |
800 |
129.2 microhm-cm |
| |
1800 |
48.0 microhm-in. |
900 |
124.9 microhm-cm |
| |
1900 |
47.6 microhm-in. |
1000 |
121.6 microhm-cm |
|
2000 |
47.6 microhm-in. |
1050 |
120.9 microhm-cm |
| |
2100 |
48.0 microhm-in. |
1100 |
121.0 microhm-cm |
| |
2200 |
48.4 microhm-in. |
1150 |
121.9 microhm-cm |
| |
- |
- |
1200 |
122.9 microhm-cm |
|
Mean Coefficient of
Thermal Expansion |
70-400 |
7.4 microinches/in.-°F |
25-200 |
13.3 x 10-6 m/m-°C |
70-600 |
7.6 microinches/in.-°F |
25-300 |
13.6 x 10-6 m/m-°C |
| |
70-800 |
7.9 microinches/in.-°F |
25-400 |
14.1 x 10-6 m/m-°C |
| |
70-1000 |
8.2 microinches/in.-°F |
25-500 |
14.6 x 10-6 m/m-°C |
| |
70-1200 |
8.6 microinches/in.-°F |
25-600 |
15.2 x 10-6 m/m-°C |
| |
70-1400 |
9.0 microinches/in.-°F |
25-700 |
15.8 x 10-6 m/m-°C |
| |
70-1600 |
9.6 microinches/in.-°F |
25-800 |
16.6 x 10-6 m/m-°C |
| |
70-1800 |
10.2 microinches/in.-°F |
25-900 |
17.6 x 10-6 m/m-°C |
70-2000 |
11.1 microinches/in.-°F |
25-1000 |
18.6 x 10-6 m/m-°C |
|
|
25-1100 |
20.2 x 10-6 m/m-°C |
|
| Thermal Conductivity |
Room |
83 Btu-in./ft.2 hr.-°F |
Room |
12.0 W/m-K |
| |
200 |
88 Btu-in./ft.2 hr.-°F |
100 |
12.8 W/m-K |
| |
400 |
99 Btu-in./ft.2 hr.-°F |
200 |
14.2 W/m-K |
| |
600 |
112 Btu-in./ft.2 hr.-°F |
300 |
15.9 W/m-K |
| |
800 |
132 Btu-in./ft.2 hr.-°F |
400 |
18.4 W/m-K |
| |
1000 |
153 Btu-in./ft.2 hr.-°F |
500 |
21.1 W/m-K |
| |
1200 |
175 Btu-in./ft.2 hr.-°F |
600 |
23.9 W/m-K |
| |
1400 |
200 Btu-in./ft.2 hr.-°F |
700 |
26.9 W/m-K |
| |
1600 |
215 Btu-in./ft.2 hr.-°F |
800 |
29.7 W/m-K |
| |
1800 |
225 Btu-in./ft.2 hr.-°F |
900 |
31.4 W/m-K |
| |
2000 |
234 Btu-in./ft.2 hr.-°F |
1000 |
32.7 W/m-K |
| |
2200 |
255 Btu-in./ft.2 hr.-°F |
1100 |
34.0 W/m-K |
| |
|
|
1200 |
36.7 W/m-K |
|
| Specific Heat |
Room |
0.108 Btu/lb.-°F |
Room |
452 J/kg-K |
| |
200 |
0.112 Btu/lb.-°F |
100 |
470 J/kg-K |
| |
400 |
0.118 Btu/lb.-°F |
200 |
493 J/kg-K |
| |
600 |
0.124 Btu/lb.-°F |
300 |
515 J/kg-K |
| |
800 |
0.130 Btu/lb.-°F |
400 |
538 J/kg-K |
| |
1000 |
0.136 Btu/lb.-°F |
500 |
561 J/kg-K |
| |
1200 |
0.154 Btu/lb.-°F |
600 |
611 J/kg-K |
| |
1400 |
0.166 Btu/lb.-°F |
700 |
668 J/kg-K |
| |
1600 |
0.173 Btu/lb.-°F |
800 |
705 J/kg-K |
| |
1800 |
0.177 Btu/lb.-°F |
900 |
728 J/kg-K |
| |
1900 |
0.178 Btu/lb.-°F |
1000 |
742 J/kg-K |
| |
2000 |
0.179 Btu/lb.-°F |
1100 |
749 J/kg-K |
| |
2200 |
0.180 Btu/lb.-°F |
1200 |
753 J/kg-K |
|
|
|
|